E-Liquid Test Results for 16 July 2013 (0713-116-03) - Enthalpy Labs (Courtesy of VapeMate)

E-Liquid Test Results for 16 July 2013 (0713-116-03) - Enthalpy Labs (Courtesy of VapeMate)

[Go Back]

Standards Legend
Component / Element Protocol
MDL*
Tolerance
Nicotine Concentration GC/FID Analysis
0.1 mg/ml
± 10%
Diethylene glycol (DEG) GC/FID Analysis
2.23 µg/ml (ppm)
No Detection
Acetaldehyde HPLC/UV Analysis
0.640 µg/ml (ppm)
< 100 µg/ml (ppm)
Acetoin HPLC/UV Analysis
0.841 µg/ml (ppm)
None Set (Informational)
Diacetyl
(2,3-Butanedione)
HPLC/UV Analysis
0.742 µg/ml (ppm)
Non-Detection Goal
< 22 µg/ml no disclosure
< 100 µg/ml (ppm) disclosure
> 100 µg/ml (ppm) is Fail
Formaldehyde HPLC/UV Analysis
0.846 µg/ml (ppm)
< 30 µg/mL (ppm)
Acetyl Propionyl
(2,3-
Pentanedione)
HPLC/UV Analysis
0.840 µg/ml (ppm)
Non-Detection Goal
< 45 µg/ml no disclosure
< 100 µg/ml (ppm) disclosure
> 100 µg/ml (ppm) is Fail
pH Level Karl Fischer Analysis Target Levels (Informational)
5.0 to 8.5
% Water Karl Fischer Analysis None Set (Informational)

* MDL - Minimum Detection Limit. The MDL will remain relatively constant but can vary slightly from test to test depending on the calibration of the equipment.

[Go Back]

These test results have been provided as a courtesy by VapeMate and they contain results of liquids that we produce.

We are unable to provide this report in its entirety since it is not our report. Please contact them directly if you wish to obtain the entire report.

16 July 2013 (0713-116-03)

Flavour Vapemate Tobacco
Non-Nic
Navy Cut Tobacco
1.2%
Dunhull Tobacco
0.8%
Sample ID VM-001 VM-002 VM-003
Enthalpy Code 0713-116-3-01 0713-116-3-02 0713-116-3-03
Nicotine Concentration
MDL: 2.04 mg/ml
ND 11.2 mg/ml 24.1 mg/ml
Diethylene glycol (DEG)
MDL: 2.23 µg/ml
ND ND ND
Acetaldehyde
MDL: 0.595 µg/ml
1.52 µg/ml 2.43 µg/ml 1.93 µg/ml
Crotonaldehyde
MDL: 0.564 µg/ml
ND ND ND
2,3-Butanedione
MDL: 0.718 µg/ml
ND 5.29 µg/ml ND
Formaldehyde
MDL: 0.549 µg/ml
11.8 µg/ml 1.39 µg/ml 1.37 µg/ml
pH 7.27 7.30 8.73
% Water 0.40% 3.50% 3.48%

ND: Non Detect or analytical result below the MDL.
J: Results flagged "J" are below the Lower Curve Limit, above the MDL, and are considered estimates.

The pages of the report showing these results are below:

Cover Page Report Page 4 Report Page 5
Report Page 6 Report Page 7 Report Page 12

[Go Back]